Shopping security
The Bently Nevada 3300/03-01-00, also cataloged as the 3300/03 System Monitor / Keyphasor Interface, serves as the primary 3300/03 System Monitor utilized to execute synchronized timing signals and serial data communication across 3300 Series platforms.
| Parameter | Specification |
|---|---|
| Model | 3300/03 |
| Brand | Bently Nevada |
| Origin | USA |
| Module Type | System Monitor / Keyphasor Interface |
| Input Voltage | 18 to 24 VDC (Via rack backplane) |
| Power Consumption | 2.0 Watts Maximum |
| Communication Port | RS232 Serial Port |
| Signal Input | Keyphasor Proximity Probe Input |
| Frequency Response | DC to 10 kHz |
| Operating Temp | -20 to +65 deg C |
| Dimensions | 33.0 cm x 5.1 cm x 20.3 cm |
| Weight | 0.7 kg |
The 3300/03-01-00 processes input thresholds from proximity transducers configured for eddy-current probe scaling to ensure precise phase-synchronous tracking. Field instrumentation routines require strict gap voltage validation, targeting a nominal -10 VDC baseline from the proximity sensor to place the physical measurement within the linear domain of the transducer calibration curve. Correct scaling prevents cross-talk suppression failures and signal clipping across the internal backplane bus, allowing downstream rack instruments to accurately extract 1X vibration amplitude, phase angle matrices, and transient rotor dynamics parameters without data distortion.
Q: What action does the 3300/03-01-00 execute if the field-side Keyphasor proximity probe signal undergoes an open-circuit or short-circuit event?
A: The module checks signal integrity parameters continuously. If the transducer voltage exits the pre-defined linear range, the internal logic drops the front-panel OK LED status and flags a system fault across the backplane to prevent invalid speed data calculation.
Q: Can the 3300/03-01-00 interface module be hot-swapped while the 3300 machinery protection rack is energized?
A: No. Removing or inserting the primary system monitor while the backplane is live interrupts the serial data backbone and common timing references, which can destabilize adjacent monitoring cards and cause unintended machine trip signals.
Q: How is the RS232 serial communication interface utilized for machinery diagnostics?
A: The integrated physical RS232 connection outputs raw and processed diagnostic data arrays directly from the backplane architecture to external host computers running automated machinery management and analysis platforms.
Ships within 48 hours · Estimated delivery Jun 27 - Jul 2
US$40
Get nowSign up to your membership to get coupons up to
15%
Get nowOpportunity to enjoy order discount up to 15% off
Top-Converting Item to Boost Your Average Order