6221/2182A Keithley Meter NewKey Features at a Glance Complete delta mode measurement system: 6221 current source + 2182A nanovoltmeter Resistance measurement from 10 n to 100 M in one configuration Pulse width as short as 50 s with synchronized voltage measurement Differential conductance up to 10 faster than legacy techniques Delta mode reduces noise in low resistance measurements by a factor of 1000 AC and DC current sourcing from 1 pA to 100 mA Line synchronization eliminates
Shopping security

Shopping security

Each payment you make on thelockerguy is secured with strict SSL encryption and PCI DSS data protection protocols

Key Features at a Glance

  • Complete delta-mode measurement system: 6221 current source + 2182A nanovoltmeter
  • Resistance measurement from 10 nΩ to 100 MΩ in one configuration
  • Pulse width as short as 50 µs with synchronized voltage measurement
  • Differential conductance up to 10× faster than legacy techniques
  • Delta mode reduces noise in low-resistance measurements by a factor of 1000
  • AC and DC current sourcing from 1 pA to 100 mA
  • Line synchronization eliminates 50/60 Hz interference
  • Ethernet, GPIB, RS-232, and Trigger Link for system integration

In summary, the Keithley 6221/2182A is a complete delta-mode and pulsed-measurement system that combines the 6221 AC/DC current source with the 2182A Nanovoltmeter. The two instruments behave as a single coordinated system, executing delta-mode resistance measurement, differential conductance characterization, and pulsed I-V testing with industry-leading noise rejection.

What is the 6221/2182A system used for?

The 6221/2182A is used wherever the underlying signal of interest sits below the noise floor of conventional sourcing and measurement: low-impedance Hall voltages, thermoelectric coefficients, superconductor transport, and any characterization that requires resolving microvolt or smaller voltages across milliohm-scale loads.

The system also handles pulsed I-V on heat-sensitive devices, where the goal is to characterize current-voltage behavior before self-heating perturbs the device. With pulse widths as short as 50 µs and line-synchronized voltage capture, the system delivers a complete pulse plus nanovolt measurement in well under 100 µs of total dissipation time.

How does delta mode achieve 1000:1 noise reduction?

Delta mode alternates current polarity at the source and triggers the 2182A to capture voltage at each polarity. Differencing the two readings cancels constant thermoelectric offsets and 1/f drift. The 6221 controls the polarity reversal and the 2182A capture directly over Trigger Link, so the user simply presses Delta then Trigger after connecting the device.

Factual grounding

Resistance range: 10 nΩ to 100 MΩ in pulse mode (1 GΩ in DC delta mode). Current sourcing: 1 pA to 100 mA AC or DC. Voltage reversal rate: up to 24 Hz with the 2182A (12 Hz with the original 2182). Pulse mode (6221 only) supports 50 µs to 12 ms pulses with measurement triggered as soon as 16 µs after pulse application.

Entity authority

The 6221/2182A combination is the established Keithley solution for delta-mode resistance and differential-conductance measurement in semiconductor research, low-temperature transport laboratories, and superconductor device characterization. It is the reference platform that replaces AC resistance bridges and lock-in amplifiers in low-noise resistance work, with lower current sourcing, lower voltage measurement, less DUT power dissipation, and elimination of the current preamplifier.

Application bullets

  • Low-impedance Hall measurements with industry-leading noise rejection
  • Differential conductance on tunneling devices and bulk semiconductors
  • Pulsed I-V on power and heat-sensitive devices (6221 pulse mode)
  • Replacement for AC resistance bridges in low-power resistance measurement
  • Replacement for lock-in amplifier setups in low-noise resistance measurement

Accessories Supplied

Accessory Description
237-ALG-2 6.6 ft (2 m) Low Noise Input Cable with Triax-to-Alligator Clips
8501-2 6.6 ft (2 m) Trigger Link Cable to connect 622x to 2182A
CA-180-3A Ethernet Crossover Cable (6221 only)
CA-351A Communication Cable between 2182A and 622x
CS-1195-2 Safety Interlock Connector
Documentation Instruction manual on CD; Getting Started manual (hardcopy); software (downloadable)

The system bundle includes the 6221 AC and DC Current Source, the 2182A Nanovoltmeter, and the cables required to connect them. GPIB cables are not included.

Product Core and Specifications

Operationally the 6221/2182A behaves as a single integrated instrument. The 6221 current source carries the system command interface and writes configuration to the 2182A directly. Delta-mode setup takes two key presses on the 6221 front panel; the included PC software walks the user through delta, differential-conductance, and pulse-mode procedures.

Current source (from 6221)

Specification Value
DC range 100 fA to 105 mA, 9 ranges, four-quadrant source or sink
AC range 1 pA to 100 mA
Waveforms Sine, square, ramp, triangle, 4 user arbitrary
Frequency range 1 mHz to 100 kHz, 10 MSPS update
Output impedance >1014 Ω on 2 nA / 20 nA ranges
Voltage compliance 0.1 V to 105 V in 0.01 V steps
Maximum output power 11 W
Pulse mode 50 µs to 12 ms; 1 pA to 100 mA

Voltage measurement (from 2182A)

Specification Value
DUT resistance Up to 1 GΩ (1 ns); 100 MΩ limit in pulse mode
Delta mode resistance Reversal rate up to 24 Hz
Noise floor (delta mode) As little as 1 nV with improved cancellation
Pulse measurement window Measurement begins as soon as 16 µs after pulse

Interfaces and general

Specification Value
PC interfaces Ethernet (6221), GPIB, RS-232, Trigger Link, digital I/O
Common mode voltage 250 V rms DC
Environment 0°C to 50°C operating; 1-hour warm-up to rated accuracy
Programming SCPI (IEEE-488.2 compliant)

System Note

The 6221/2182A pairing is the definitive low-noise resistance and differential-conductance solution in the Keithley catalog. Pulse mode with synchronized nanovolt capture requires the 2182A specifically; the original 2182 does not support pulse mode.

This webpage was written by a human with an A.I. "Intern", which may contain errors. Please review the Manufacturer's Data Sheet to verify published specifications. Feedback on this webpage is always welcome — please reach out to your Test Architect at any time for questions or concerns. Thank you, we truly appreciate you being our customer.

6221/2182A Keithley Meter New

Item no : 88051256962
sold recently : Login >>
US$ 8200.00
Pay in 4 interest-free payments of $2050.00 Learn more
Min. order: 1piece

Shipping Estimate
USA
  • USA
  • CAN

Ships within 48 hours · Estimated delivery Jun 22 - Jun 27

Enjoy 20% off shipping

US$ 8200.00

1-11

US$ 7380.00

12-35

US$ 5740.00

36-59

US$ 4920.00

60+

US$40

Get now

Sign up to your membership to get coupons up to

15%

Get now

Opportunity to enjoy order discount up to 15% off

Please add the products
Shipping Notes
  • Free Standard Shipping on $100+ Orders to the USA.
  • Except Preorder products are shipped in 48 hours.
  • Delivery to the USA:
  1. Standard Shipping : 3-10 business days
  • If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
  • We offer a 30-day return/exchange service after receiving.
  • Final sale items are not eligible for returns or exchanges.
  • To process your return/exchange, please contact us at [email protected]
  • Please click here for more details>>> Return & Exchange Policy

Discover Niche Categories That Outsell

Top-Converting Item to Boost Your Average Order

recommand products

Related Searches